Phuket Thailand EANx Nitrox and Rebreather Diving
|
|
Depth |
Air NDL |
EANx 32 NDL |
EANx 36 NDL |
|
18 m |
56 min |
95 min |
125 min |
|
22m |
37 min |
60 min |
70 min |
|
26m |
27 min |
40 min |
50 min |
Diving with Nitrox provides longer no-decompression times compared to diving with air, but its use requires training to account for considerations not normally associated with recreational air diving. PADIs Enriched Air Nitrox Course addresses these considerations and teaches you how to benefit the most by diving with Nitrox. In addition the PADI Enriched Air Instructor Course teaches the Instructor how to successfully organize, plan and market Nitrox training for recreational divers.
As a certified Nitrox Diver you can rent Nitrox tanks from our filling station, adding a new dimension to your diving adventures.
We already have numerous labels such as "Enriched Air Nitrox", "EANx", "Safe Air", "Nitrox" and others. Nitrox in simplest terms is merely a mixture of nitrogen gas and oxygen gas. Air, therefore, is naturally occurring nitrox for all practical purposes. In diving, however, "nitrox" usually means a nitrogen-oxygen mix other than air, normally with more than 21% oxygen.
To avoid confusion over the various possible nitrox mixes, besides the simple designation "nitrox", its frequently referred to with a number reflecting oxygen content, such as "Nitrox 36". This would mean a nitrox mix of 36% oxygen and 64% nitrogen. The common names, "Nitrox I" or "EANx32" and "Nitrox II" or "EANx36", refer to 32% and 36% oxygen mixtures, respectively, that the U.S. National Oceanic and Atmospheric Administration (NOAA) uses as nitrox standard mixes, and which are by far the most commonly used mixes in general.
As every certified diver knows decompression limits and the potential for decompression illness are caused by the inert nitrogen component of breathing air. Nitrogen also causes nitrogen narcosis at deeper depths. Nitrox was conceived as a way to reduce the nitrogen breathed during a dive.
By replacing nitrogen in the breathing gas with oxygen, the divers body absorbs less nitrogen for a given depth and time. Since the body metabolizes oxygen, in theory oxygen doesnt contribute to decompression illness, so a diver breathing EANx32, for example, should have longer no-decompression limits at a given depth than when breathing air. If decompression stops become necessary, a shorter decompression schedule would be required. Alternatively, the diver could base his decompression schedule as though he was breathing air, with the reduced nitrogen acting as an extra safety factor. In either case, nitrogen narcosis should theoretically be reduced somewhat compared to breathing air at the same depth.
Nitrox is not intended for extremely deep diving. As we will see, EANx32 becomes unsafe at depths not much greater than the recreational maximum limit of 40 meters, with higher oxygen mixes limited to even shallower maximum depths. Sometimes nitrox becomes confused as a deep diving gas because commercial and technical divers frequently use nitrox as a decompression gas following deep dives. However, these divers dont begin using nitrox until returning to shallower depths.
Since the start more than thirty years ago, nitrox has been used successfully by closely supervised and well-trained military, scientific, commercial and technical divers. Though it hasnt had as much formal testing as air, nitrox safety record has been very good. Doppler tests have been made, with low or no detectable bubble formation when diving within table limits. In working dives, nitrox isnt associated with any higher DCI rate than diving with air. Used properly there doesnt appear to be any greater risk diving with nitrox than diving with air.
The key words are "when used properly". Diving with nitrox provides longer no-decompression times compared to diving with air, but its use requires training to account for considerations not associated with recreational diving with air. The first consideration is that while there is only one type of air there are potentially 78 mixes of nitrox with more than 21% oxygen. (Nitrox calculations normally assume that plus or minus 1% variation is tolerable in a nitrox mix, so fractions of a percent are not treated as separate mixes. Nitrox with 31.6%, 32% and 32.3 oxygen are all considered EANx32). Each of the 78 mixes differs in no-decompression limits and decompression schedules.
The most common way to handle this is to convert the actual depth into an Equivalent Air Depth (EAD) that may be used with air tables. This is accomplished by using a simple formula. For example, at a depth of 25 meters using EANx36, the EAD would be 18,4 meters; the diver would use the no-decompression limits from that depth (rounded to 20 meters). Using the EAD concept, any nitrox mix can be used with air tables. In the above example, nitroxs decompression advantage become immediately noticable: 45 minutes no-decompression time is available at 25 meters, compared to only 29 minutes using air, depending upon the air table used. Alternatively, the diver could plan the dive as an air dive, creating a 16-minute safety factor.
To simplify nitrox use, nitrox tables have been developed. NOAA released tables for EANx32 in 1978, and for EANx36 in the early 1980s; these tables are used exactly like the standard U.S. Navy tables. In fact, these tables are simply the U.S. Navy tables rewritten with the actual depth replaced by the calculated EAD. Besides these, other organizations, such as various navies around the world, have nitrox tables and finally PADIs RDP32 and RDP36 where introduced to recreational divers in 1995/96. In using nitrox tables the diver must be sure that he uses the appropriate table for the particular mix he will be breathing.

Unfortunately, nitroxs nitrogen advantages are gained only at the price of oxygen disadvantages. When using nitrox, exposure to dangerously high oxygen partial pressures becomes possible at depths far shallower than with air. Nitrox mixtures with more than 32% oxygen cannot even be taken to the 40-meter depth limit for recreational diving.
The problem is Central Nervous System (CNS) oxygen toxicity, which, depending upon exposure duration, becomes a potential risk when oxygen partial pressures exceed critical limits. A case of CNS oxygen toxicity causes the diver to convulse and lose consciousness, and may or may not be proceeded by warning symptoms. Convulsions are not dangerous themselves, but an unconscious diver will lose his regulator and drown.
Critical oxygen limits vary drastically with partial pressure. A diver can tolerate .6 Ata oxygen partial pressure for up to twelve hours without significant risk of CNS symptoms. At 1.6 Ata, which is the maximum acceptable p.p., the time is about 45 minutes, possibly shorter than the no-decompression limit of the equivalent air depth. The nitrox diver monitors his p.p./time allowances to make certain he doesnt exceed his "oxygen clock", in much the same way he watches no-decompression limits. Minimum surface intervals must be noted as well.
As the oxygen percentage in nitrox increases, the depth at which the critical 1.6 limit is reached rises. When breathing air the diver reaches 1.6 Ata at 66.5 meters. Breathing EANx32 1.6 Ata is reached at 40.3 meters; and with EANx36, 34,6 meters. Below these depths, the risk of CNS oxygen toxicity goes up dramatically.
With the increase in technical diving and nitrox use, there have been quite a few conflicting reports about whether standard scuba equipment is compatible with nitrox.
NOAAs policies since the 70s have been:
Standard air equipment, except the tank, may be used with any nitrox mix, which has 40% or less oxygen without any modification.
Equipment being used with mixes with more than 40 % oxygen, OR used for oxygen mixing must be oxygen compatible.
This means that for nitrox mixes with 40 % or less oxygen, which are the most common mixes, a nitrox diver can use the same equipment that he uses for air diving. The tank is an exception to the 40 % guideline, and needs to be oxygen compatible regardless of oxygen content in the nitrox. The reason the tank must be oxygen compatible is that a common method for mixing nitrox is partial pressure mixing. This is done by adding 100 % oxygen to the cylinder, then topping of with air thats filtered to oxygen compatible standards. Even if the final mix may be less than 40 % oxygen, exposure to 100 % oxygen during mixing requires oxygen compatibility. Besides oxygen compatibility, nitrox tanks should be clearly marked to avoid confusion with air tanks. This is important considering that using a mix with more than 32 % oxygen, a diver can exceed the maximum oxygen depth limit while within the traditional 40-meter recreational depth limit.
Nitrox also requires at least one specialized piece of equipment: the oxygen analyzer. While the nitrox diver doesnt need to own one, the diver must confirm the mixs oxygen content personally after the tank has been filled. This safety procedure ensures use of the correct EADs and calculation of oxygen p.p.
Mixing nitrox isnt as simple as pumping compressed air. In fact, while the air in a typical dive store meets the standards for compressed air diving, it frequently does not meet the higher standards required for mixing nitrox. This means that even an oxygen compatible cylinder with oxygen already in it cannot simply be topped off with air from a typical dive store compressed air system. Doing so actually creates a risk of fire or explosion. To avoid these complications, nitrox diver training emphasizes these points; the nitrox diver learns that the typical dive store isnt capable of providing nitrox (yet). Specialized dive stores and operations have and use appropriate nitrox mixing equipment. The point is that safe nitrox mixing requires special equipment, and like nitrox diving, requires special training.
Used properly, there appears to be no greater safety concern with diving with nitrox than with diving with air. Used improperly, nitrox poses oxygen toxicity risks more readily than air.
Nitrox diving requires special training in table use, oxygen limits, equipment compatibility and oxygen analyzer use.
Dive
operations interested in mixing nitrox must be prepared to invest in the
training and required training to do so safely.
To learn more about Nitrox Diving Courses with IDC Phuket, please utilize our inquiry form.

HOME | IDC
| CON-ED | SIGN-UP
| PRE-STUDY | SCHEDULE
& PRICES
BJORN | CAREER | TEC
| NEWS
Bjorn Tackmann IDCs - in association with Dive
Asia
Phuket's first and only PADI 5 Star Career Development Center!
Please e-mail Bjorn with your questions, comments or ideas.
Visit our mirror sites:
IDC Phuket |
Rebreather Diving | IDC
Planet | Phuket
Diving
Web hosting and maintenance by Bjorn Tackmann
Web design by avalon-webdesign.com
More info about Phuket
© 1997-2003 Bjorn Tackmann - all rights reserved.
P.O. Box 46, 83150 Phuket, Thailand.
Tel: +66 (0) 1 895 3866 and +66 (0) 76 333 212 | Fax: +66 (0) 76 292 581
E-mail: bjorn@cdc-phuket.com
![]()